1.
Cureus ; 16(3): e56595, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38646368

RESUMO

Background When metals used in orthodontic materials are exposed to the oral environment, teeth, and gingivae over an extended period of time, they may gradually deteriorate. As a result, the patient is exposed to higher concentrations of metals and metal ions than what they would be exposed to through food and other sources. The goal of the current in vitro experiment was to evaluate and contrast the metal ion release from orthodontic archwires made of titanium-molybdenum alloy (TMA) and nickel-titanium (NiTi). Methods For 90 days, 20 orthodontic archwires in each group were immersed in 50 milliliters of simulated saliva using different containers. Atomic Absorption Spectrometry (AAS) (Shimadzu Corporation, Kyoto, Japan) was used to assess and compare metal ion emission. The unit of measurement is parts per million (PPM). Results The findings indicated that the discharge of nickel metal from the NiTi archwire (Group A) was much higher than that from the TMA archwire (Group B), with a statistical significance level of p < 0.001. It was discovered that Group B's release of titanium was statistically significantly (p < 0.05) higher than Group A's titanium release, which did not include the release of any other metals. Conclusion The study findings indicated that the amounts of metal ions released from the orthodontic archwires made of titanium molybdenum and nickel-titanium alloy were within safety limits.